Blizzard hotstik 5 cob Instrukcja Użytkownika Strona 7

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 6
Page 7
HotStik™ 5 COB User Manual - Rev. A (c) 2014 Blizzard Lighting, LLC
3. SETUP
Fuse Replacement
CAUTION! The HotStik™ 5 COB utilizes a high-output switch-mode power
supply with an internal fuse. Under normal operating conditions, the fuse
shouldnotrequirereplacement.Thefuseiseldreplaceable,however
itisanadvancedproceduresuitedtoqualiedindividuals.Shouldyour
HotStik™5COBfuserequirereplacement,pleasecontactBlizzardLighting
for instructions, or to return your unit for service.
Connecting A Bunch of HotStik™ 5 COB Fixtures
You will need a serial data link to run light shows using a DMX-512
controllerortorunshowsontwoormorexturessettosyncinmaster/
slaveoperatingmode.Thecombinednumberofchannelsrequiredbyall
thexturesonaserialdatalinkdeterminesthenumberofxturesthe
data link can support.
Fixtures on a serial data link must be daisy chained in one single line.
Also,connectingmorethan32xturesononeserialdatalinkwithoutthe
use of a DMX optically-isolated splitter may result in deterioration of the
digital DMX signal. The maximum recommended cable-run distance is 500
meters(1640ft).Themaximumrecommendednumberofxturesona
serialdatalinkis32xtures.
Data/DMX Cabling
Tolinkxturestogetheryou’llneeddatacables.Youshouldusedata-
gradecablesthatcancarryahighqualitysignalandarelessproneto
electromagnetic interference.
Forinstance,Belden©9841meetsthespecicationsforEIARS-485
applications. Standard microphone cables will “probably” be OK, but note
that they cannot transmit DMX data as reliably over long distances. In
any event, the cable should have the following characteristics:
2-conductor twisted pair plus a shield
Maximum capacitance between conductors – 30 pF/ft.
Maximum capacitance between conductor & shield – 55 pF/ft.
Maximum resistance of 20 ohms / 1000 ft.
Nominal impedance 100 – 140 ohms
Przeglądanie stron 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 19 20

Komentarze do niniejszej Instrukcji

Brak uwag